This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwQinQBpduTunnelTable

hwQinQBpduTunnelTable

hwQinQBpduTunnelTable is set in the Layer 2 interface view.

The index of this table is hwQinQBpduTunnelIndex.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.116.2.1.1.1

hwQinQBpduTunnelIndex

Integer

Not-accessible

The value of this object identifies the interface index.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.116.2.1.1.3

hwQinQBpduTunnelEnableOneQBpduTunnel

EnabledStatus

Read-write

The value of this object identifies whether the function of the BPDU tunnel with one tag is enabled.

  • 1:enabled
  • 2:disabled

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.116.2.1.1.4

hwQinQBpduTunnelEnableBpduTag

EnabledStatus

Read-only

This object indicates that BPDUs are transparently transmitted across the public network.

  • 1:enabled
  • 2:disabled

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.116.2.1.1.5

hwQinQBpduTunnelEnableTwoQBpduTunnel

EnabledStatus

Read-only

This object indicates whether the interface permits the BPDUs with tags to pass.

  • 1:enabled
  • 2:disabled

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.116.2.1.1.6

hwQinQBpduTunnelCustomerBpduTag

Integer

Read-write

This integer specifies the number of tags to be added during the transparent transmission of BPDUs to distinguish the subnets of different BPDUs.

The value ranges from 0 to 4094.0 indicates the default configuration, and the flag to delete a configured.

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

No entry can be created in this table.

Modification Restriction

  • Before hwQinQBpduTunnelEnableTwoQBpduTunnel is enabled, hwQinQBpduTunnelCustomerBpduTagListLow, hwQinQBpduTunnelCustomerBpduTagListHigh cannot be set.

  • Before hwQinQBpduTunnelEnableBpduTag is enabled, hwQinQBpduTunnelCustomerBpduTag cannot be set.

  • The settings of hwQinQBpduTunnelEnableOneQBpduTunnel and hwQinQBpduTunnelEnableTwoQBpduTunnel, hwQinQBpduTunnelCustomerBpduTagListLow, hwQinQBpduTunnelCustomerBpduTagListHigh are mutually exclusive.

  • The settings of hwQinQBpduTunnelEnableBpduTag, hwQinQBpduTunnelCustomerBpduTag and hwQinQBpduTunnelEnableTwoQBpduTunnel, hwQinQBpduTunnelCustomerBpduTagListLow, hwQinQBpduTunnelCustomerBpduTagListHigh are mutually exclusive.

Deletion Restriction