No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

MIB Reference

S12700 V200R010C00

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwDot3ahEfmManagerTable

hwDot3ahEfmManagerTable

This table is used to configure the auto-recovery delay before an interface goes administratively Up and EFM OAM being associated with an interface.

The index of this table is ifIndex.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.136.1.2.2.8.1.1

hwDot3ahEfmTriggerIfDown

EnabledStatus

Read-write

The value of this object identifies whether EFM OAM is associated with an interface. The value can be:
  • enabled: indicates that EFM OAM is associated with an interface. After EFM OAM of an interface detects a connectivity fault, EFM on the interface goes Down. As a result, services on the interface are interrupted.

  • disabled: indicates that EFM OAM is not associated with an interface.

By default, the value is disabled.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.136.1.2.2.8.1.2

hwDot3ahEfmHoldUpTime

Integer32 (0..50)

Read-write

This object indicates the auto-recovery delay before an interface goes administratively Up.

The value ranges from 0 to 50, in seconds.

The default value is 0.

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

The entries in this table can be created only after EFM is enabled globally.

Modification Restriction

The entries in this table can be modified only after EFM is enabled globally.

Deletion Restriction

None.

Access Restriction

The entries in this table can be read only after EFM is enabled globally.

Translation