MIB Reference

S12700 V200R010C00

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwTunnelTeStatisticsTable

hwTunnelTeStatisticsTable

The table describes the up/down state transition counts of the TE tunnel interface and the time stamp at which the interface is hot plugged out or at which the device performs active/standby switchover.

The index of this table is hwTunnelTeStatisticsIfIndex.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.151.1.5.1.1

hwTunnelTeStatisticsIfIndex

InterfaceIndex

Not-accessible

This object indicates the index of the TE tunnel interface. The value is a 32-bit unsigned integer.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.151.1.5.1.2

hwTunnelTeUpDownStatistics

Unsigned32

Read-only

Describes the up/down transition counts of the TE tunnel interface.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.151.1.5.1.3

hwTunnteCounterDiscontinuityTime

TimeStamp

Read-only

The value of sysUpTime on the most recent occasion at which this interface's up/down transition counters suffered a discontinuity.

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

This table does not support creation at present.

Modification Restriction

This table does not support modification at present.

Deletion Restriction

This table does not support deletion at present.

Access Restriction

The entries in this table can be read only there is a TE tunnel in the monitored device.