Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwMplsOamIgrTable

hwMplsOamIgrTable

hwMplsOamIgrTable describes the OAM feature of the source end of the detected LSP. It provides the following functions:

  • Creating, modifying and deleting OAM instances

  • Configuring the parameters of OAM, including the tunnel name bound to the detected LSP, OAM detection parameters, reverse channel parameters, and the enable flag

  • Querying the detection status, including whether the configuration takes effect, LSP availability status, and defect status

The index of this table is hwMplsOamIgrIndex.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.12.7.1.1.2.1.1

hwMplsOamIgrIndex

Unsigned32

accessible-for-notify

This object indicates the index of the OAM ingress entry of the LSP ingress.

The value ranges from 1 to 4294967296.

There is no default value.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.12.7.1.1.2.1.2

hwMplsOamIgrTunnName

OCTET STRING

Read-create

This object indicates the name of the tunnel bound to the LSP.

The value is a string of a maximum of 16 characters.

There is no default value.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.12.7.1.1.2.1.3

hwMplsOamIgrDetType

INTEGER {cv(1), ffd(2)}

Read-create

The value of this object identifies the OAM detection type.

Values are as follows:

  • CV (1)
  • FFD (2)

The default value is 1.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.12.7.1.1.2.1.4

hwMplsOamIgrDetFreq

INTEGER {cv1000ms(0), ffd10ms2(1), ffd20ms3(2), ffd50ms4(3), ffd100ms5(4), ffd200ms6(5), ffd500ms7(6), ffd3ms8(7)}

Read-create

The value of this object identifies the OAM detection frequency.

Values are as follows:

  • 1s (0)
  • 10 ms (1)
  • 20 ms (2)
  • 50 ms (3)
  • 100 ms (4)
  • 200 ms (5)
  • 500 ms (6)
  • 7: 3ms

The default value is 0.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.12.7.1.1.2.1.5

hwMplsOamIgrRevType

INTEGER {private(1), share(2)}

Read-create

The value of this object identifies the reverse channel type.

Values are as follows:

  • exclusive (1)
  • shared (2)

The default value is 2.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.12.7.1.1.2.1.6

hwMplsOamIgrRevLspName

OCTET STRING

Read-create

This object indicates the name of the reverse LSP.

The value is a string of a maximum of 16 characters.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.12.7.1.1.2.1.7

hwMplsOamIgrRevLsrId

IpAddress

Read-create

This object indicates the LSR ID of the reverse channel.

The value is a four-byte IP address.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.12.7.1.1.2.1.8

hwMplsOamIgrRevSessTunnId

Integer32 (0..65535)

Read-create

The value of this object identifies the tunnel ID of the reverse channel.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.12.7.1.1.2.1.9

hwMplsOamIgrEnable

INTEGER {disable(0), enable(1)}

Read-create

The value of this object identifies whether the OAM detection is enabled.

Values are as follows:

  • disable (0)
  • enable (1)

The default value is 0.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.12.7.1.1.2.1.10

hwMplsOamIgrValid

Integer32 (0..1)

Read-only

The value of this object identifies whether OAM configuration takes effect.

Values are as follows:

  • 0: invalid, indicating that detection does not start.
  • 1: valid, indicating that detection starts.

There is no default value.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.12.7.1.1.2.1.11

hwMplsOamIgrAvaState

Integer32 (0..1)

Read-only

The value of this object identifies the LSP availability status.

Values are as follows:

  • available (0)
  • unavailable (1)

There is no default value.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.12.7.1.1.2.1.12

hwMplsOamIgrDefectType

Integer32 (0..9)

Read-only

The value of this object identifies the LSP defect type.

Values are as follows:

  • No defect (0)
  • dServer (1)
  • dPeerme (2)
  • dLocv (3)
  • dTTSI_Mismatch (4)
  • dTTSI_Mismerge (5)
  • dExcess (6)
  • dUnknown (7)
  • RLSN Down (8)
  • dIngressDown (9)

There is no default value.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.12.7.1.1.2.1.13

hwMplsOamIgrRowStatus

RowStatus

Read-create

The value of this object identifies the entry operation mode.

Values are as follows:

  • active (1)
  • not in service (2)
  • not ready (3)
  • create and go (4)
  • create and wait (5)
  • destroy (6)

There is no default value.

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

The creation restrictions are as follows:

  • When the hwMplsOamIgrDetType is 1, hwMplsOamIgrDetFreq can only be 0. When the hwMplsOamIgrDetType is 2, hwMplsOamIgrDetFreq can be any integer from 1 to 6.

  • hwMplsOamIgrRowStatus is set to 4.

  • When creating new entries, you must set hwMplsOamIgrTunnName and hwMplsOamIgrRowStatus, but cannot set hwMplsOamIgrIndex, hwMplsOamIgrValid, hwMplsOamIgrAvaState, and hwMplsOamIgrDefectType. Other parameters take the default values if not configured.

Modification Restriction

The modification restrictions are as follows:

  • When modifying entries, you can set only hwMplsOamIgrDetType, hwMplsOamIgrDetFreq, hwMplsOamIgrRevType, hwMplsOamIgrRevLspName, hwMplsOamIgrRevLsrId, and hwMplsOamIgrRevSessTunnId, but cannot set the other parameters.

  • hwMplsOamIgrDetType and hwMplsOamIgrDetFreq must be set at the same time. When hwMplsOamIgrDetType is 1, hwMplsOamIgrDetFreq can only be 0. When the hwMplsOamIgrDetType is 2, the hwMplsOamIgrDetFreq can be any integer from 1 to 6.

Deletion Restriction

The deletion restrictions are as follows:

  • When deleting entries, you need to set hwMplsOamIgrTunnName and hwMplsOamIgrRowStatus, but cannot set the other parameters.

  • hwMplsOamIgrTunnName takes the default value, and hwMplsOamIgrRowStatus is set to 6.

Accessing Restriction

The entries in this table can be read without restraint.