No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

MIB Reference

S12700 V200R010C00

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwEntityStateTable

hwEntityStateTable

This table describes the status of the entity such as the status of management, operation, backup, CPU usage and high threshold, and memory usage and high threshold.

The index of this table is entPhysicalIndex.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.1

hwEntityAdminStatus

HwAdminState

Read-write

Management status of the entity. The values are as follows:

  • 1: notSupported
  • 2: locked
  • 3: shuttingDown
  • 4: unlocked

Default value: 4

Currently, the maximum access is read-only.

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.2

hwEntityOperStatus

HwOperState

Read-only

Operating status of the entity. The values are as follows:

  • 1: notSupported
  • 2: disabled
  • 3: enabled
  • 4: offline

Default value: 3

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.3

hwEntityStandbyStatus

HwStandbyStatus

Read-only

Backup status of the entity. The values are as follows:

  • 1: notSupported
  • 2: hotStandby
  • 3: coldStandby
  • 4: providingService

Default value: 1

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.5

hwEntityCpuUsage

Integer32

Read-only

CPU usage of the entity.

Value range: 2-100

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.6

hwEntityCpuUsageThreshold

Integer32

Read-write

High threshold of the CPU usage of the entity.

Value range: 2-100

Default value: 80

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.7

hwEntityMemUsage

Integer32

Read-only

Memory usage of the entity.

Value range: 0-100

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.8

hwEntityMemUsageThreshold

Integer32

Read-write

Threshold of the memory usage of the entity. Value range: 75-100

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.9

hwEntityMemSize

Integer32

Read-only

Memory capacity of the entity, in bytes.

NOTE:

If the memory capacity exceeds 2147483647 bytes, this object displays -1, indicating an invalid value.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.10

hwEntityUpTime

Integer32

Read-only

Time to start the entity, in seconds.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.11

hwEntityTemperature

Integer32

Read-only

Highest entity temperature displayed in the sensor, in °C.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.12

hwEntityTemperatureThreshold

Integer32

Read-write

High threshold of the entity temperature, in °C.

Currently, the maximum access is read-only.

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.13

hwEntityVoltage

Integer32

Read-only

Voltage of the entity, in mV.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.14

hwEntityVoltageLowThreshold

Integer32

Read-write

Low threshold of the entity voltage, in mV.

Currently, the maximum access is read-only.

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.15

hwEntityVoltageHighThreshold

Integer32

Read-write

High threshold of the entity voltage, in mV.

Currently, the maximum access is read-only.

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.16

hwEntityTemperatureLowThreshold

Integer32

Read-write

Low temperature threshold of the entity, in °C.

Currently, the maximum access is read-only.

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.19

hwEntityMemSizeMega

Integer32

Read-only

Memory capacity of the entity, in M.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.29

hwEntityCpuMaxUsage

Integer32

Read-only

The Max CPU usage of the entity.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.43

hwEntityBoardName

OCTET STRING

Read-only

Entity name.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.47

hwEntitySplitAttribute

OCTET STRING

read-only

Port name before port split.

If no port name is displayed, this port is not a split port.

This object is implemented as defined in the corresponding MIB file.

Creation Restriction

No entry can be created in this table.

Modification Restriction

Only the read-write objects can be modified.

Deletion Restriction

The entries in this table cannot be deleted.

Access Restriction

The entries in this table can be read without restriction.

Translation
Download
Updated: 2019-08-21

Document ID: EDOC1000142096

Views: 176864

Downloads: 80

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next