Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwUSAConfigTable

hwUSAConfigTable

This table describes the interface configuration on an access device. The interface can be configured as the access point.

The index of this table is hwUSAPortIndex.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.40.20.1.1.1.1

hwUSAPortIndex

Integer32

read-only

This object indicates the interface index. The value ranges from 1 to 32767.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.40.20.1.1.1.2

hwUSAInterfaceName

Octet String

read-only

This object indicates the interface name. The value ranges from 1 to 64.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.40.20.1.1.1.3

hwAuthenAccessPoint

EnabledStatus

read-write

This object indicates whether the interface is enabled as the access point.
  • 1: enabled
  • 2: disabled

The default value is disabled.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.40.20.1.1.1.4

hwAuthenAccessPointMaxUser

Integer32

read-write

This object indicates the maximum number of access users allowed on an interface of an access device.

The value varies according to device models:
  • S2720EI, S2750EI and S5700S-LI: 128
  • S5320EI, S6320EI, S5720EI, S6720EI and S6720S-EI: 512
  • Other models: 256

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.40.20.1.1.1.5

hwAuthenAccessPointOpen

EnabledStatus

read-write

This object indicates whether the access point disables its right control.
  • 1: enabled
  • 2: disabled

The default value is disabled.

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

You can create entries in this table.

Modification Restriction

The entries in this table can be modified.

Deletion Restriction

The entries in this table can be deleted.

Access Restriction

The entries in this table can be read without restriction.

Translation
Download
Updated: 2019-08-21

Document ID: EDOC1000142096

Views: 180221

Downloads: 80

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next