MIB Reference

S12700 V200R010C00

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwVplsAcTable

hwVplsAcTable

This table lists ACs configured in the VSI. You cannot create or delete the AC entry of a VSI.

The indexes of this table are hwVplsVsiName and hwVplsAcIfIndex.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.119.1.1.3.1.1

hwVplsAcIfIndex

InterfaceIndex

Not-accessible

The value of the object identifies the index of the interface that is bound to the VSI.

One interface can be bound to only one VSI.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.1.1.3.1.2

hwVplsAcStatus

Integer{up(1),down(2),}

Read-only

The value of this object identifies the status of the AC interface. The values are as follows:

  • 1: Up
  • 2: Down

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.1.1.3.1.3

hwVplsAcUpStartTime

DisplayString (SIZE (0..63))

Read-only

This object indicates the time when the AC interface is restored last time.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.1.1.3.1.4

hwVplsAcUpSumTime

Unsigned32

Read-only

This object indicates the duration when the AC interface is Up.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.1.1.3.1.51

hwVplsAcRowStatus

RowStatus

Read-create

This object indicates the row status of this table. You are unable to modify the entry after creating it.

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

None.

Modification Restriction

The entries in this table cannot be modified.

Deletion Restriction

The entries in this table cannot be deleted.

Access Restriction

The entries in this table can be read without restraint.

Translation