Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwUserGroupTable

hwUserGroupTable

hwUserGroupTable is a user group configuration table. You can use this table to configure user authorization information in a user group.

The index of this table is hwUserGroupIndex.

NOTE:

The functions provided by this MIB only apply to the NAC common mode.

OID

Object Name

Syntax

Implemented Specifications

Description

Status

1.3.6.1.4.1.2011.5.2.1.51.1.1

hwUserGroupIndex

Integer32

read-only

This object indicates the user group index. The value ranges from 1 to 128.

current

1.3.6.1.4.1.2011.5.2.1.51.1.2

hwUserGroupName

DisplayString

read-create

This object indicates the user group name. The value ranges from 1 to 64.

current

1.3.6.1.4.1.2011.5.2.1.51.1.3

hwAclId

DisplayString

read-create

This object indicates the ID of an ACL configured in a user group. A maximum of eight ACLs can be configured. Two ACLs are separated by a space and each ACL must exist on the device. When this table takes effect, ACLs in the original user group are deleted.

current

1.3.6.1.4.1.2011.5.2.1.51.1.7

hwUserGroupRowStatus

Integer32

read-create

This object indicates the row status of a user group. The row status can be created and deleted.

current

1.3.6.1.4.1.2011.5.2.1.51.1.8

hwUserVlan

Integer32

read-create

This object indicates the VLAN to which the user group belongs to. The value ranges from 1 to 4094.

current

1.3.6.1.4.1.2011.5.2.1.51.1.9

hw8021pRemark

Integer32

read-create

This object indicates the priority for processing Ethernet Layer 2 packets. The value ranges from 0 to 7.

current

1.3.6.1.4.1.2011.5.2.1.51.1.10

hwDscpRemark

Integer32

read-create

This object indicates the priority for processing IP packets. The value ranges from 0 to 63.

current

1.3.6.1.4.1.2011.5.2.1.51.1.13

hwUserGroupCarCir

Unsigned32

read-write

This object indicates the CIR of the user group. The value is 0 or ranges from 64 to 4294967295. The default value is 0. 0 indicates that the CIR is not configured for the user group.

current

1.3.6.1.4.1.2011.5.2.1.51.1.14

hwUserGroupCarPir

Unsigned32

read-write

This object indicates the PIR of the user group. The value is 0 or ranges from 64 to 4294967295. The default value is 0. 0 indicates that the PIR is not configured for the user group.

current

1.3.6.1.4.1.2011.5.2.1.51.1.15

hwUserGroupCarCbs

Unsigned32

read-write

This object indicates the CBS of the user group. The value is 0 or ranges from 10000 to 4294967295. The default value is 0. 0 indicates that the CBS is not configured for the user group.

current

1.3.6.1.4.1.2011.5.2.1.51.1.16

hwUserGroupCarPbs

Unsigned32

read-write

This object indicates the PBS of the user group. The value is 0 or ranges from 10000 to 4294967295. The default value is 0. 0 indicates that the PBS is not configured for the user group.

current

1.3.6.1.4.1.2011.5.2.1.51.1.17

hwUserGroupEnable

INTEGER

read-write

This object indicates whether the user group function is enabled.
  • 1: enable (1): The user group function is enabled.
  • 2: disable (2): The user group function is disabled.

current

1.3.6.1.4.1.2011.5.2.1.51.1.18

hwUserGroupCarInBoundCir

Unsigned32

read-write

This object indicates the CIR value of incoming packets in the user group. The value is 0 or ranges from 64 to 4294967295. The default value is 0. 0 indicates that the CIR is not configured for the user group.

current

1.3.6.1.4.1.2011.5.2.1.51.1.19

hwUserGroupCarInBoundPir

Unsigned32

read-write

This object indicates the PIR value of incoming packets in the user group. The value is 0 or ranges from 64 to 4294967295. The default value is 0. 0 indicates that the PIR is not configured for the user group.

current

1.3.6.1.4.1.2011.5.2.1.51.1.20

hwUserGroupCarInBoundCbs

Unsigned32

read-write

This object indicates the CBS value of incoming packets in the user group. The value is 0 or ranges from 10000 to 4294967295. The default value is 0. 0 indicates that the CBS is not configured for the user group.

current

1.3.6.1.4.1.2011.5.2.1.51.1.21

hwUserGroupCarInBoundPbs

Unsigned32

read-write

This object indicates the PBS value of incoming packets in the user group. The value is 0 or ranges from 10000 to 4294967295. The default value is 0. 0 indicates that the PBS is not configured for the user group.

current

1.3.6.1.4.1.2011.5.2.1.51.1.22

hwUserGroupUserVlanPool

OCTET STRING

read-create

This object indicates the VLAN pool bound to the user group.

current

Creation Restriction

Before configuring a VLAN or an ACL, ensure that the VLAN or ACL has been created.

Modification Restriction

The bound user group cannot be modified. You cannot modify the configuration of the user group that has been enabled.

Deletion Restriction

This table cannot be deleted when any user exists in the user group.