MIB Reference

S12700 V200R010C00

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwDhcpSnpBindTblAutosaveFilename

hwDhcpSnpBindTblAutosaveFilename

NOTE:

This object must be set together with the hwDhcpSnpBindTblAutosave object. When multiple variables are set, the name in hwDhcpSnpBindTblAutosaveFilename is hwDhcpSnpBindTblAutosaveFilename.0 and the name in hwDhcpSnpBindTblAutosave is hwDhcpSnpBindTblAutosave.0.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.112.1.8

hwDhcpSnpBindTblAutosaveFilename

DisplayString ( SIZE ( 1..51 ) )

Read-write

This object indicates the file name used when the binding table is backed up to the hard disk. The file is saved in full path, such as flash:/bind.tbl.

This object is implemented as defined in the corresponding MIB files.