Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwTwampResponderTable

hwTwampResponderTable

hwTwampResponderTable is used to configure the Responder. It issues configurations to the Responder through the NMS.

The index of this table is hwTwampResponderId.

OID

Object Name

Syntax

Maximum Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.333.1.2.1.1.1

hwTwampResponderId

Integer32

not-accessible

This object indicates the index of the measurement instance. The value ranges from 1 to 10.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.333.1.2.1.1.2

hwTwampResponderSourceIpAddressType

InetAddressType

read-create

This object indicates the IP address type of the measurement instance Responder.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.333.1.2.1.1.3

hwTwampResponderSourceIpAddress

InetAddress

read-create

This object indicates the IP address of the measurement instance Responder.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.333.1.2.1.1.4

hwTwampResponderDestIpAddressType

InetAddressType

read-create

This object indicates the IP address type of the measurement instance Sender.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.333.1.2.1.1.5

hwTwampResponderDestIpAddress

InetAddress

read-create

This object indicates the IP address of the measurement instance Sender.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.333.1.2.1.1.6

hwTwampResponderSourceUDPPort

Integer32

read-create

This object indicates the UDP port number of the Responder in the measurement instance. The value is 862, 863, or an integer that ranges from 1025 to 65535.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.333.1.2.1.1.7

hwTwampResponderDestUDPPort

Integer32

read-create

This object indicates the UDP port number of the Sender in the measurement instance. The value is 862, 863, or an integer that ranges from 1025 to 65535.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.333.1.2.1.1.10

hwTwampResponderVrfName

DisplayString

read-create

This object indicates the VPN instance name of the measurement instance Responder.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.333.1.2.1.1.12

hwTwampResponderDescription

DisplayString

read-create

This object indicates the description of the measurement instance Responder.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.333.1.2.1.1.99

hwTwampResponderRowStatus

RowStatus

read-create

This object indicates the row status of the measurement session.
  • 1: active
  • 2: notInService
  • 3: notReady
  • 4: createAndGo
  • 5: createAndWait
  • 6: destroy

This object is implemented as defined in the corresponding MIB file.

Creation Restriction

hwTwampSenderId is the unique identifier of an instance. Different instances cannot use the same hwTwampSenderId.

Modification Restriction

The parameters in this table cannot be modified. To modify an instance, delete it and create it again.

Deletion Restriction

The entries in this table can be deleted without restriction.

Access Restriction

This table supports only the Get operation, but does not support the Get-Next operation.