Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwTrngCreateTimerangeTable

hwTrngCreateTimerangeTable

This table is used to create a time range. You have to create a time range in the MIB first. After that, you can create the sub period time and sub absolute time subordinate to it.

The index of this table is hwTrngIndex.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.13.1.1.1.1

hwTrngIndex

Integer32 (1..256)

Not-accessible

The value of this object identifies the table index.

The value ranges from 1 to 256.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.13.1.1.1.2

hwTrngName

OCTET STRING (SIZE (1..32))

Read-create

This object indicates the name of the time range.

The value is a string of up to 32 characters, beginning with a character.

Read-create

1.3.6.1.4.1.2011.5.25.13.1.1.1.3

hwTrngValidFlag

TruthValue

Read-only

The object indicates whether the time range is valid.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.13.1.1.1.4

hwTrngCreateRowStatus

RowStatus

Read-create

This object indicates the row status of the table.

Currently, the status of CreateAndGo and destroy is realized.

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

To create the entries in this table, you need to specify hwTrngName and hwTrngCreateRowStatus. hwTrngValidFlag is a read-only field. Only the row status of CreateAndGo can be created.

Modification Restriction

The entries of this table cannot be modified.

Deletion Restriction

The entries of this table can be deleted. You need to specify hwTrngName and destroy of row status.