MIB Reference

S12700 V200R010C00

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwPWVcTable

hwPWVcTable

This table is a PW configuration table. You can create and delete a PW by using this table.

For the switching PW, related objects of the switch can support the function of query according to the first VC ID.

The indexes of this table are hwPwVcID and hwPwVcType.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.1

hwPWVcID

Unsigned32(0 to 4294967295)

Not-accessible

The value of this object identifies the VC ID.

The object is a decimal integer that ranges from 1 to 4294967295. The default value is 0.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.2

hwPWVcType

HWL2VpnVcEncapsType

Not-accessible

This object indicates the encapsulation type of the PW. For details, see hwPwVcType.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.3

hwPWVcPeerAddrType

InetAddressType

Read-create

The value of this object identifies the type of the peer IP address.

  • 0: unknown address
  • 1: IPv4 address
  • 2: IPv6 address
  • 3: IPv4z address
  • 4: IPv6z address
  • 16: DNS

Currently, the maximum access is read-only.

At present, this object supports only IPv4 addresses. Besides, if the protocol type of the PW is unknown, the value of this object is also unknown.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.4

hwPWVcPeerAddr

IpAddress

Read-create

This object indicates the peer IP address of the PW.

If the type of hwPwVcPeerAddrType is unknown, the peer IP address of the PW is all 0s.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.5

hwPWVcStatus

Integer{up(1),down(2),plugout(3),backup(4)}

Read-only

The value of this object identifies the PW status of the local node.

  • 1: Up
  • 2: Down
  • 3: Plugout
  • 4: Backup

At present, this object does not support the plugout status.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.6

hwPWVcInboundLabel

Unsigned32

Read-create

The object indicates the value of the incoming label. The value is automatically allocated by the system.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.7

hwPWVcOutboundLabel

Unsigned32

Read-create

The object indicates the value of the outgoing label. The value is automatically allocated by the system.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.8

hwPWVcSwitchSign

Integer{staticTostatic (1)ldpTostatic (2)ldpToldp (3)upe(4)}

Read-only

The value of this object identifies the type of the switching PW.

  • 1: static-to-static switching
  • 2: dynamic-to-static switching
  • 3: dynamic-to-dynamic switching
  • 4: UPE

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.9

hwPWVcSwitchID

Unsigned32(0 to 4294967295)

Read-create

This object indicates the ID of the switching VC. The object is a decimal integer that ranges from 1 to 4294967295. The default value is 0.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.10

hwPWVcSwitchPeerAddrType

InetAddressType

Read-create

The value of this object identifies the peer IP address type of the switching PW.

  • 0: unknown address
  • 1: IPv4 address
  • 2: IPv6 address
  • 3: IPv4z address
  • 4: IPv6z address
  • 16: DNS

Currently, the maximum access is read-only.

At present, this object supports only IPv4 addresses. Besides, if the protocol type of the PW is unknown, the value of this object is also unknown.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.11

hwPWVcSwitchPeerAddr

IpAddress

Read-create

This object indicates the peer IP address of the switching PW.

If the type of hwPwSwitchVcPeerAddrType is unknown, the peer IP address of the switching PW is all 0s.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.12

hwPWVcSwitchInboundLabel

Unsigned32

Read-create

This object indicates the incoming label value of the switching PW.

  • For the static PW, the object is a decimal integer that ranges from 16 to 1023.
  • For the dynamic PW, the object is automatically allocated by the system.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.13

hwPWVcSwitchOutboundLabel

Unsigned32

Read-create

This object indicates the outgoing label value of the switching PW.

  • For the static PW, the object is a decimal integer that ranges from 16 to 1023.
  • For the dynamic PW, the object is automatically allocated by the system.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.14

hwPWVcGroupID

Unsigned32

Read-create

This object indicates the ID of the VC group.

At present, this object is not supported. The value is 0.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.15

hwPWVcIfIndex

InterfaceIndexOrZero

Read-create

This object indicates the index of the AC interface that is associated with the PW.

The value 0 indicates that the index of the interface is invalid.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.16

hwPWVcAcStatus

INTEGER { up(1), down(2), plugout(3), notify(4), notifyDown(5), downNotify(6) }

Read-only

The value of this object identifies the status of the AC interface.

At present, this object does not support the plugout status.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.18

hwPWVcMtu

Integer32

Read-create

This object indicates the MTU value of the AC interface on the local node that is associated with the PW. The object is a decimal integer that is 0 or ranges from 46 to 9600. The default MTU value is 1500.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.19

hwPWVcCtrlWord

HWEnableValue

Read-create

The value of this object identifies the capability of the control word.

  • 1: enable
  • 2: disable

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.20

hwPWVcVCCV

BITS

{

ccCw(0),

ccAlert(1),

ccLabel(2),

cvIcmpping(3),

cvLspping(4),

cvBfd(5),

ccTtl(6)

}

Read-create

This object indicates the optional VCCV capabilities of the PW. According to whether the control word is enabled, the value can be ccCw(0)|ccAlert(1)|cvLspping(4)|cvBfd(5) or ccAlert(1)|ccTtl(6)|cvLspping(4)|cvBfd(5).

The default value is ccAlert(1)|ccTtl(6)|cvLspping(4)|cvBfd(5).

  • 0: control channel of the control word (ccCw)
  • 1: control channel of the MPLS router alert (ccAlert)
  • 4: LSP ping connectivity verification (cvLspping)
  • 5: BFD connectivity verification (cvBfd)
  • 6: control channel of the time to live (ccTtl)

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.23

hwPWVcTnlPolicyName

Octet String(size(0..39))

Read-create

This object indicates the name of the tunnel policy. The name is a string of 0 to 19 characters. By default, the length of the name is 0.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.26

hwPWVcTemplateName

Octet String(size(0..19))

Read-create

This object indicates the name of the PW module. The object is a case-sensitive string of 0 to 19 characters. If the value of the object is not specified, the default value is 0.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.27

hwPWVcSecondary

TruthValue

Read-create

The value of this object identifies whether the PW is a backup PW.

  • 1: true (backup PW)
  • 2: false (non-backup PW)

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.28

hwPWVcUpTime

Unsigned32

Read-only

This object indicates the duration when the PW keeps Up for the last time, in seconds.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.30

hwPWVCForBfdIndex

Unsigned32

Read-only

This object indicates the index of BFD for PW.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.31

hwPWVcDelayTime

Unsigned32

Read-create

This object indicates the delay time of PW switching.

The object is a decimal integer, expressed in seconds.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.32

hwPWVcReroutePolicy

Integer{delay(1), immediately(2), never(3), none(4), err(5), invalid(6), immediatelySwitch(7)}

Read-create

The value of this object identifies the switching policy of a PW.

  • 1: indicates that the switching is Down after a certain period of delay.
  • 2: indicates the immediate switching.
  • 3: indicates that the recovered master PW does not switch to be the master until the backup PW fails.
  • 4: none.
  • 5: indicates that the switching policy is incorrect.
  • 6: indicates that the switching policy is unavailable.
  • 7: indicates that in the PW redundancy scenario, the traffic immediately switches to the master PW after the master PW recovers.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.33

hwPWVcResumeTime

Unsigned32

Read-create

This object indicates the delay time of PW switching after resumption.

The object is a decimal integer, expressed in seconds.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.34

hwPWVcRerouteReason

HWL2VpnStateChangeReason

Read-only

This object indicates the reason of PW switching.

For details, see hwPwStateChangeReason.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.35

hwPWVcLastRerouteTime

Unsigned32

Read-only

This object indicates the time of the last switching of PW.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.36

hwPWVcManualSetFault

TruthValue

Read-create

The value of this object identifies whether the fault flag is manually set.

  • 1: true (set)
  • 2: false (unset)

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.37

hwPWVcActive

TruthValue

Read-only

The value of this object identifies whether the current PW is in the Active state.

  • 1: true (active)
  • 2: false (inactive)

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.40

hwPWBFDDetectMultiplier

Unsigned32(0|3-50)

Read-create

This object indicates the local BFD detection multiple.

The value ranges from 3 to 50. If the BFD detect function is not enabled, the value is 0.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.41

hwPWBFDMinReceiveInterval

Unsigned32 (0 | 3..1000)

Read-create

This object indicates the interval for receiving BFD packets.

The value ranges from 3 to 1000, in milliseconds. If the BFD detect function is not enabled, the value is 0.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.42

hwPWBFDMinTransmitInterval

Unsigned32 (0 | 3..1000)

Read-create

This object indicates the interval to send BFD packets.

The value ranges from 3 to 1000, expressed in milliseconds.

If the BFD detect function is not enabled, the value is 0.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.43

hwPWDynamicBFDDetect

TruthValue

Read-create

The value of this object identifies whether the dynamic BFD for PW is supported.

  • 1: true (supported)
  • 2: false (unsupported)

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.44

hwPWBFDRemoteVcID

Unsigned32(0 to 4294967295)

Read-create

In the case of multiple segments, this object indicates the peer VC ID.

The value ranges from 1 to 4294967295. The default value is 0.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.47

hwPWVcUpStartTime

DisplayString (SIZE (0..63))

Read-only

This object indicates the time when the PW returns to the Up state last time.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.48

hwPWVcUpSumTime

Unsigned32

Read-only

This object indicates the accumulated time when the VC is Up, in seconds.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.49

hwPWVcIfName

DisplayString (SIZE (0..63))

Read-only

Indicates the name of a VC interface.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.51

hwPWVcRowStatus

RowStatus

Read-create

This object indicates the row status of this table.

Restriction:

  • To create this table, you must adopt the CreatAndGo processing mode, rather than the CreatAndWait processing mode.

After creating this table, you are unable to modify the configuration.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.57

hwPWVcSwitchTnlPolicyName

OCTET STRING (SIZE (0..19))

Read-create

Indicates the switch tunnel policy name used.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.61

hwPWVcRawOrTagged

INTEGER { raw(1), tagged(2), rawTagNotConfiged(3) }

Read-only

Specifies whether the VLAN tag of the VC entry is attached or stripped.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.62

hwPWVcInterworkingType

INTEGER { ipInterWorking(1), ipLayer2(2), ipUnknown(3) }

Read-only

Specifies the interworking type of the VC entry.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.69

hwPWVcTrigger

TruthValue

Read-create

Specifies whether the PW remote interface shutdown or not.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.74

hwPWVcBfdParaFromPWT

INTEGER { liOrMib(1), pwTemplate(2), unknown(3) }

Read-only

This object indicates the configuration of the BFD parameters managed through command line or PW template.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.1.1.1.98

hwPwVcSwitchCwTrans TruthValue Read-create This object indicates whether the SPE support Control Word Transparent or not, and the default value is false.

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

None.

Modification Restriction

The entries in this table can be modified.

  • The hwPWOAMSync, hwPWVcReroutePolicy, hwPWVcManualSetFault, hwPWDynamicBFDDetect, and hwPWVcTrigger support the modification of single-segment PWE3 only.
  • The hwPWVcSwitchCir and hwPWVcSwitchVrID support the modification of multi-segment PWE3 only.
  • The hwPWVcPeerAddr, hwPWVcSwitchPeerAddr, hwPWVcDelayTime, hwPWVcResumeTime, hwPWVcVrIfIndex, hwPWBFDDetectMultiplier, hwPWBFDMinReceiveInterval, hwPWBFDMinTransmitInterval, hwPWBFDRemoteVcID, hwPWEthOamType, hwPWVcCfmMaName, hwPWVcCfmMdName, hwPWVcEnableACOAM, and hwPWVcSwitchVrIfIndex cannot be modified independently. Instead, it takes affect only after cooperation with another modification.

Deletion Restriction

None.

Access Restriction

None.

Translation
Download
Updated: 2019-04-20

Document ID: EDOC1000142096

Views: 115246

Downloads: 75

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next