Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwEthernetTable

hwEthernetTable

This table describes the access and configuration of physical attributes of various Ethernet interfaces.

The index of this table is hwEthernetIfIndex.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.157.1.1.1.1.1

hwEthernetIfIndex

InterfaceIndex

Not-accessible

This object indicates the index of a current in-position interface.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.157.1.1.1.1.13

hwEthernetSpeedSet

INTEGER {

other(1),

speed10(2),

speed100(3),

speed1000(4),

speed10000(5),

speed40000(6),

speed20000(7),

speed100000(10),

}

Read-write

The value of this object identifies the transmission rate of an Ethernet interface.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.157.1.1.1.1.14

hwEthernetDuplex

INTEGER{

full(1),

half(2)

}

Read-write

This object indicates the duplex mode of an Ethernet interface.

Ethernet electrical interfaces can work in either half-duplex or full-duplex mode. Ethernet optical interfaces can only work in full-duplex mode.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.157.1.1.1.1.15

hwEthernetNegotiation

EnabledStatus

Read-write

The value of this object identifies the auto-negotiation mode on an Ethernet electrical interface. By default, the value is enable.

hwEthernetSpeedSet, hwEthernetDuplex, and hwEthernetNegotiation are associated with each other.

  • If hwEthernetNegotiation is set to enable, the values of hwEthernetSpeedSet and hwEthernetDuplex are obtained through auto-negotiation.
  • hwEthernetSpeedSet and hwEthernetDuplex can be set only when hwEthernetNegotiation is set to disable.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.157.1.1.1.1.37

hwEthernetJumboframeMaxLength

INTEGER32(1536..12288)

Read-write

The value of this object identifies the maximum frame length allowed by an Ethernet interface.

The value varies according to device models. For details, see jumboframe enable.

1.3.6.1.4.1.2011.5.25.157.1.1.1.1.38

hwEthernetComboType

INTEGER

1: auto(1)

2: copper(2)

3: fiber(3)

4: other(4)

Read-write

This object indicates the working mode of the combo interface.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.157.1.1.1.1.39

hwEthernetPortMode

INTEGER

1: copper(1)

2: fiber(2)

3: other(3)

Read-only

This object indicates the working mode of the interface.

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

No entry can be created in this table.

Modification Restriction

The entries in this table can be modified.

Deletion Restriction

No entry in this table can be deleted.

Access Restriction

None.

Translation