No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Huawei SAN Storage Host Connectivity Guide for VMware ESXi

HUAWEI SAN Storage Host Connectivity Guide for VMware ESXi Servers

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
UltraPath

UltraPath

Storage System Configuration

If you use UltraPath, retain the default initiator settings. Do not select Use third-party multipath software.

Figure 6-4 Initiator setting when UltraPath is used

Host Configuration

Install UltraPath by following instructions in the OceanStor UltraPath for vSphere User Guide.

After you install UltraPath, set the trespass policy for LUNs as follows:

  • This configuration must be performed on all hosts separately. Retain the default settings for other parameters.
  • If a LUN is mapped to multiple ESXi hosts in a cluster as VMFS datastores, raw devices (RDM), or virtual volumes (VVols), the host LUN IDs of the LUN for all of these ESXi hosts must be the same. You are advised to add all ESXi hosts in a cluster that are served by the same storage device to a host group and to the same mapping view.
  • For UltraPath earlier than 21.2.0, it is recommended that you run the set luntrespass command to disable the trespass policy.
    # esxcli upadm set luntrespass -m off 
    Succeeded in executing the command.
    The command format is set luntrespass [ -a array-id | -l vlun-id ] -m mode. Table 6-3 describes the key parameters in the command.
    Table 6-3 Parameter description

    Parameter

    Description

    Default Value

    -a array-id

    ID of the storage array

    You can run the show diskarray command to query the ID of the storage array.

    None

    -l vlun-id

    ID of the virtual LUN

    You can run the show vlun command to query the IDs of all virtual LUNs.

    None

    -m mode

    Trespass policy of LUNs

    • on: Switchover of LUNs' working controller is enabled.
    • off: Switchover of LUNs' working controller is disabled.

    on

  • For UltraPath 21.2.0 and later, it is recommended that you retain the default settings (the trespass policy is disabled by default).
Download
Updated: 2020-01-17

Document ID: EDOC1000144883

Views: 144273

Downloads: 7315

Average rating:
This Document Applies to these Products

Related Version

Related Documents

Share
Previous Next