Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Direct-Attached iSCSI Connections

Direct-Attached iSCSI Connections

Huawei provides dual-controller and multi-controller storage systems, which directly connect to SUSE hosts through iSCSI multi-path connections in different ways.

Two-Controller Storage

The following uses Huawei OceanStor 5500 V3 as an example to explain how to directly connect a SUSE host to a two-controller storage system through iSCSI multi-path connections, as shown in Figure 3-5.

Figure 3-5 Direct-attached iSCSI multi-path connections (two-controller storage)

NOTE:

In this connection diagram, each of the two controllers is connected to a port on the host network adapter with a network cable. The IP address plan is detailed in Table 3-6.

Table 3-6 IP address plan for direct-attached iSCSI multi-path connections (two-controller storage)

Port Name

Port Description

IP Address

Subnet Mask

Host.P0

Connects the SUSE host to Controller A on the storage system.

192.168.5.5

255.255.255.0

Host.P1

Connects the SUSE host to Controller B on the storage system.

192.168.6.5

255.255.255.0

Storage.A.P0

Connects Controller A on the storage system to the SUSE host.

192.168.5.6

255.255.255.0

Storage.B.P0

Connects Controller B on the storage system to the SUSE host.

192.168.6.6

255.255.255.0

NOTE:

IP addresses in this table are for reference only. Plan IP addresses based on site requirements.

Multi-Controller Storage

The following uses Huawei OceanStor 18800 V3 (four-controller) as an example to explain how to directly connect a SUSE host to a multi-controller storage system through iSCSI multi-path connections, as shown in Figure 3-6.

Figure 3-6 Direct-attached iSCSI multi-path connections (four-controller storage)

NOTE:

In this connection diagram, each of the four controllers is connected to a port on host network adapters with a network cable. The IP address plan is detailed in Table 3-7.

Table 3-7 IP address plan for direct-attached iSCSI multi-path connections (four-controller storage)

Port Name

Port Description

IP Address

Subnet Mask

Host.P0

Connects the SUSE host to Controller A on the storage system.

192.168.5.5

255.255.255.0

Host.P1

Connects the SUSE host to Controller B on the storage system.

192.168.6.5

255.255.255.0

Host.P2

Connects the SUSE host to Controller C on the storage system.

192.168.7.5

255.255.255.0

Host.P3

Connects the SUSE host to Controller D on the storage system.

192.168.8.5

255.255.255.0

Storage.A.P0

Connects Controller A on the storage system to the SUSE host.

192.168.5.6

255.255.255.0

Storage.B.P0

Connects Controller B on the storage system to the SUSE host.

192.168.6.6

255.255.255.0

Storage.C.P0

Connects Controller C on the storage system to the SUSE host.

192.168.7.6

255.255.255.0

Storage.D.P0

Connects Controller D on the storage system to the SUSE host.

192.168.8.6

255.255.255.0

NOTE:

IP addresses in this table are for reference only. Plan IP addresses based on site requirements.