Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Setting SOL Session Timeout Period (sol -d timeout)

Setting SOL Session Timeout Period (sol -d timeout)

Function

The sol -d timeout command is used to set the timeout period for SOL sessions. If no operation is performed within the specified timeout period, the SOL session will be automatically disconnected and the iBMC CLI is displayed.

Format

ipmcset -t sol -d timeout -v <value>

Parameters

Parameter

Description

Value

value

Maximum idle time (in minutes) after the last operation on the SOL session. If no operation is performed within the specified time, the SOL session will be automatically disconnected.

Value range: 0 to 480

The value 0 indicates unlimited time.

Default value: 15

Usage Guidelines

Only iBMC V256 and later versions support this command.

The switch module does not support the command.

Example

# Set the SOL session timeout period to 20 minutes.

iBMC:/->ipmcset -t sol -d timeout -v 20
Set SOL timeout period successfully. 