Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Modifying RAID Controller Properties (ctrlconfig)

Modifying RAID Controller Properties (ctrlconfig)

Function

The ctrlconfig command is used to modify RAID controller properties.

Format

ipmcset -t storage -d ctrlconfig -v <control_id> <[-cb <cbstate>] [-smartercb <smartercbstate>] [-jbod <jbodstate>] [-restore]

Parameters

Parameter

Description

Value

control_id

Specifies the ID of the RAID controller.

0 to 255
cbstate Specifies the setting of copyback of the RAID controller.
  • enabled
  • disabled
smartercbstate Specifies whether copyback is enabled when a SMART error is detected on a member disk of the RAID controller.
  • enabled
  • disabled
jbodstate Specifies the setting of JBOD of the RAID controller.
  • enabled
  • disabled

Usage Guidelines

If the command contains -restore, the RAID controller properties will be restored to default values.

This command can be used only when either of the following conditions is met:
  • The RAID controller card supports iBMC out-of-band management. You can refer to the Technical Specifications section in the RAID controller card user guide to determine whether the RAID card supports the iBMC out-of-band management.
  • The iBMA 2.0 has started on the OS.

Example

# Enable copyback for RAID controller 0.

iBMC:/-> ipmcset -t storage -d ctrlconfig -v 0 -cb enabled 
WARNING: The operation may have many adverse effects.
Do you want to continue?[Y/N]:y