ALM-0x06000007 RAID Controller Card MCE/AER Error (RAID Card, Critical Alarm)
Description
Alarm message:
The arg3 RAID controller card arg1 triggered an uncorrectable error, arg2 (SN: arg4, BN: arg5).
This alarm is generated when an uncorrectable error occurs on a RAID controller card.
Alarm object: RAID card
Parameters
Name | Meaning |
---|---|
arg1 |
Slot number of the RAID controller card. |
arg2 |
Error code of the alarm. |
arg3 |
Front I/O module or compute module and its slot number, for example, FM or CMn. |
arg4 |
SN of the RAID controller card. |
arg5 |
BOM code. |
Impact on the System
The RAID controller card may run unstably or be faulty. The system may even stop responding.
Possible Causes
- The RAID controller card is faulty.
- The BBU of the RAID controller card is faulty.
- The mainboard is faulty.
Procedure
- Remove and reinstall the RAID controller card. Then, check whether the alarm is cleared.
If yes, no further action is required.
If no, go to 2.
- Replace the RAID controller card. Then, check whether the alarm is cleared.
If yes, no further action is required.
If no, go to 3.
- Replace the BBU of the RAID controller card. Then, check whether the alarm is cleared.
If yes, no further action is required.
If no, go to 4.
- Replace the mainboard. Then, check whether the alarm is cleared.
If yes, no further action is required.
If no, go to 5.
- Contact technical support.