ALM-0x0000000B CPU Undervoltage (CPU, Major Alarm)
Description
Alarm message:
CPU arg1 core voltage (arg2 V) is lower than the undervoltage threshold (arg3 V).
From iBMC V316, the CPU and disk alarms will also include the SN and BOM code and the mainboard and memory alarms will also include the BOM code.
This alarm is generated when the voltage of the CPU arg1 Core on the mainboard is lower than the undervoltage major threshold.
Alarm object: CPU
Attribute
Alarm ID |
Alarm Severity |
Auto Clear |
---|---|---|
0x0000000B |
Major |
Yes |
Parameters
Name | Meaning |
---|---|
arg1 |
Socket No. of the CPU. |
arg2 |
Current reading of the sensor. |
arg3 |
Alarm threshold. |
Procedure
- Switch the CPU with a functioning CPU in the same chassis, and check whether the alarm is still generated for this CPU.
- Replace the CPU. Then, check whether the alarm is cleared.
If yes, no further action is required.
If no, go to 4.
- Replace the mainboard. Then, check whether the alarm is cleared.
If yes, no further action is required.
If no, go to 4.
- Contact technical support.