ALM-0x0D000003 NIC Overtemperature (NIC, Minor Alarm)
Description
Alarm message:
The NIC arg1 temperature (arg2 degrees C) exceeds the overtemperature threshold (arg3 degrees C).
This alarm is generated when the PCIe card temperature exceeds the overtemperature minor threshold.
Alarm object: NIC
Parameters
Name | Meaning |
---|---|
arg1 |
Serial number of the NIC. |
arg2 |
Current reading of the sensor. |
arg3 |
Alarm threshold. |
Possible Causes
A fan module is faulty.
The equipment room temperature exceeds the normal range.
The air inlet or outlet is blocked.
A NIC is faulty.
Procedure
- Check whether there are fan module alarms.
- Replace the fan module. After 5 minutes, check whether the alarm is cleared.
If yes, no further action is required.
If no, go to 3.
- Check whether the equipment room temperature exceeds the normal range.
- Reduce the equipment room temperature to the normal range. After 5 minutes, check whether the alarm is cleared.
If yes, no further action is required.
If no, go to 5.
- Check whether the air inlet or outlet of the server is blocked.
- Clear the blockage. After 5 minutes, check whether the alarm is cleared.
If yes, no further action is required.
If no, go to 7.
- Replace the NIC. Then, check whether the alarm is cleared.
If yes, no further action is required.
If no, go to 8.
- Contact technical support.