ALM-0x1A00002F NAND Flash Service Life Lower Than Threshold (BMC, Major Alarm)
ALM-0x1A00002F NAND Flash Service Life Lower Than Threshold (BMC, Major Alarm)
Description
Alarm message:
The service life of the NAND flash is less than arg1.
This alarm is generated when the system detects that the remaining service life of the iBMC Nand flash is lower than the threshold.
Alarm object: BMC
iBMC V296 and later support this alarm.
Attribute
Alarm ID
Alarm Severity
Auto Clear
0x1A00002F
Major
No
Parameters
Name
Meaning
arg1
NAND flash service life threshold, for example, 95 or 90.
Impact on the System
The iBMC cannot operate properly.
Possible Causes
The remaining service life of the iBMC NAND flash reaches the threshold.
Procedure
Replace the mainboard. Then, check whether the alarm is cleared.