ALM-0x1000007B Failed to Read MOSFET Voltage Difference (Mainboard, Minor Alarm)
Description
Alarm message:
Failed to obtain the MOS [arg1] FET voltage drop of the soft-start circuit (BN: arg2).
From iBMC V316, the CPU and disk alarms will also include the SN and BOM code and the mainboard and memory alarms will also include the BOM code.
This alarm is generated when the system failed to obtain the voltage difference of the MOSFET on the mainboard.
Alarm object: mainboard
Parameters
Name | Meaning |
---|---|
arg1 |
Number of the monitoring point of the soft-start circuit. |
arg2 |
BOM code. |
Impact on the System
The voltage cannot be monitored. No alarm will be reported when the voltage is not in the normal range.
Procedure
- Restart the iBMC. Then, check whether the alarm is cleared.
If yes, no further action is required.
If no, go to 2.
- Remove and reinstall the power cable or board. Then, check whether the alarm is cleared.
If yes, no further action is required.
If no, go to 3.
- Replace the mainboard. Then, check whether the alarm is cleared.
If yes, no further action is required.
If no, go to 4.
- Contact technical support engineer.