No relevant resource is found in the selected language.
Your browser version is too early. Some functions of the website may be unavailable. To obtain better user experience, upgrade the browser to the latest version.
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document.
Note: Even the most advanced machine translation cannot match the quality of professional translators.
Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x0100003F Failed to Read Memory Temperature (Memory, Minor Alarm)
ALM-0x0100003F Failed to Read Memory Temperature (Memory, Minor Alarm)
Description
Alarm message:
Failed to obtain data of the memory (arg1) temperature.
The alarm does not include the SN or BOM code of the component.
This alarm is generated when the system failed to obtain the memory temperature.
Alarm object: memory
Attribute
Alarm ID
Alarm Severity
Auto Clear
0x0100003F
Minor
Yes
Parameters
Name
Meaning
arg1
DIMM silkscreen or CPU socket number and memory channel No.
DIMM silkscreen, for example, DIMM010(B).
CPU socket number and channel number.
NOTE:
The number of DIMMs corresponding to a memory channel varies depending on the server model.
You can obtain the CPU socket number and channel number corresponding to a DIMM from the Computing Product Memory Configuration Assistant.
Impact on the System
The temperature cannot
be monitored. No alarm will be reported when the temperature is not
in the normal range.
Possible Causes
The ME is faulty, or the access channel is abnormal.
Procedure