ALM-0x2900002F NIC Port Linkdown (Port, Major Alarm)
Description
Alarm message:
arg1 [arg2] arg3 disconnected.
This alarm is generated when the NIC port linkdown occurs.
Alarm object: Port
iBMC V3.01.12.21 and later support this alarm.
Attribute
Alarm ID |
Alarm Severity |
Auto Clear |
---|---|---|
0x2900002F |
Major |
Yes |
Parameters
Name |
Meaning |
---|---|
arg1 |
NIC name, for example, "NIC", "PCIe Card", "LOM", or "iBMC dedicated port". |
arg2 |
Type of the NIC, for example, (NIC) or (FC). |
arg3 |
Network port number, for example, "port 1". |
Impact on the System
The network port services will be interrupted.
Possible Causes
The network cable is not connected or the port of the peer device is not connected.
Procedure
- Remove and reconnect the network cable. Then check whether the alarm is cleared.
- If yes, no further action is required.
- If no, go to 2.
- Check whether the network cable is connected to the peer device.
- Connect the network cable to the peer device port correctly. Then check whether the alarm is cleared.
- If yes, no further action is required.
- If no, go to 4.
- Check whether the peer device works properly.
- Replace the faulty peer device. Then check whether the alarm is cleared.
- If yes, no further action is required.
- If no, go to 6.
- Contact technical support engineer.