ALM-0x2C000075 Failed RAID Array Detected (System, Major Alarm)
Description
Alarm message:
Failed RAID array detected.
This alarm is generated when a failed or abnormal RAID array is detected in the system.
Alarm object: system
Procedure
- Check all the RAID arrays. If there is any RAID array in abnormal status, do as follows:If the RAID array has a member drive removed, install a drive in the empty slot. Then, check whether the alarm is cleared.
- If yes, no further action is required.
If no, go to 2.
If there is faulty drive, replace the faulty drive. Then, check whether the alarm is cleared.
For details about how to replace the drive, see the user guide of the server you use.
After replacing the drive, restore the drive data. For details, see "Drive Faults" in the user guide of the RAID controller card you use.
- If yes, no further action is required.
If no, go to 2.
- Contact technical support engineer.