ALM-0x0100001F Failed to Read VDDQ1 Voltage of the DIMM Connected to the CPU (Memory, Minor Alarm)
Description
Alarm message:
Failed to obtain data of the CPU arg1 DIMM VDDQ1 voltage.
The alarm does not include the SN or BOM code of the component.
This alarm is generated when the sensor access channel is abnormal, or the sensor chip has failed.
Alarm object: memory
Impact on the System
The voltage cannot be monitored. No alarm will be reported when the voltage is not in the normal range.
Procedure
- Restart the iBMC. Then, check whether the alarm is cleared.
If yes, no further action is required.
If no, go to 2.
- Remove and reinstall the power cable or board. Then, check whether the alarm is cleared.
If yes, no further action is required.
If no, go to Contact the device vendor's technical support engineer..
- Contact technical support engineer.