ALM-0x0600000D Failed to Read RAID Controller Card Temperature (RAID Card, Minor Alarm)
Description
Alarm message:
Failed to obtain data of the arg2 RAID controller card arg1 temperature (SN: arg3, BN: arg4).
From iBMC V328, the RAID controller card and PSU alarms will also include the SN and BOM code, and the fan alarms will also include the BOM code.
This alarm is generated when the system failed to obtain the RAID controller card temperature.
Alarm object: RAID card
Parameters
Name | Meaning |
---|---|
arg1 |
Slot number of the RAID controller card. |
arg2 |
Front I/O module or compute module and its slot number, for example, FM or CMn. |
arg3 |
SN of the RAID controller card. |
arg4 |
BOM code. |
Impact on the System
The temperature cannot be monitored. No alarm will be reported when the temperature is not in the normal range.
Procedure
- Restart the iBMC. Then, check whether the alarm is cleared.
If yes, no further action is required.
If no, go to 2.
- Remove the power cable to power off the server, and then reconnect the power cable to power on the server. Then, check whether the alarm is cleared.
If yes, no further action is required.
If no, go to 3.
- Replace the RAID controller card. Then, check whether the alarm is cleared.
If yes, no further action is required.
If no, go to 4.
- Contact technical support.