ALM-0x18000007 High temperature of soft-start circuit of the fan backplane (Fan Backplane, Critical Alarm)
Description
Alarm message:
High temperature of soft-start circuit arg1 of the fan backplane.
This alarm is generated when the high temperature of soft-start circuit of the fan backplane.
Alarm object: Fan Backplane
Attribute
Alarm ID |
Alarm Severity |
Auto Clear |
---|---|---|
0x18000007 |
Critical |
Yes |
Parameters
Name |
Meaning |
---|---|
arg1 |
Voltage detection point. For example, 12V0_HD_OUT. |
Impact on the System
The power supply of server drives will be affected. As a result, the drives cannot function properly.
Possible Causes
The fan backplane is faulty.
Procedure
- Replace the fan backplane and check whether the alarm is cleared.
- If yes, no further action is required.
- If no, go to 2.
- Contact technical support engineer.