ALM-0x01000009 Memory VDDQ2 Overvoltage (Memory, Major Alarm)
Description
Alarm message:
CPU arg1 DIMM VDDQ2 voltage (arg2 V) exceeds the overvoltage threshold (arg3 V).
The alarm does not include the SN or BOM code of the component.
This alarm is generated when the voltage of the CPU arg1 DIMM VDDQ2 on the mainboard exceeds the overvoltage major threshold.
Alarm object: memory
Parameters
Name | Meaning |
---|---|
arg1 |
Socket No. of the CPU. |
arg2 |
Current reading of the sensor. |
arg3 |
Alarm threshold. |
Procedure
- Remove the DIMMs connected to the CPU one by one, and check whether the alarm is cleared.
Use the Computing Product Memory Configuration Assistant to obtain information about the mapping between CPUs and DIMMs.
- Replace the faulty DIMM. Then, check whether the alarm is cleared.
If yes, no further action is required.
If no, go to 4.
- Replace the mainboard. Then, check whether the alarm is cleared.
If yes, no further action is required.
If no, go to 4.
- Contact technical support.