ALM-0x10000089 Failed to Read Mainboard Electronic Label Data (Mainboard, Minor Alarm)
ALM-0x10000089 Failed to Read Mainboard Electronic Label Data (Mainboard, Minor Alarm)
Description
Alarm message:
Failed to obtain electronic label data of mainboard (BN: arg1).
From iBMC V316, the CPU and disk alarms will also include the SN and BOM code and the mainboard and memory alarms will also include the BOM code.
This alarm is generated when the system failed to obtain the electronic label data.
Alarm object: mainboard
Attribute
Alarm ID
Alarm Severity
Auto Clear
0x10000089
Minor
Yes
Parameters
Name
Meaning
arg1
BOM code.
Impact on the System
The system cannot obtain asset information.
Possible Causes
The iBMC is abnormal.
The mainboard is abnormal.
Procedure
Restart the iBMC. Then, check whether the alarm is cleared.