Direct-Attached iSCSI Connections
Huawei provides dual-controller and multi-controller storage systems, which directly connect to Solaris hosts through iSCSI multi-path connections in different ways.
Two-Controller Storage
The following uses Huawei OceanStor 5500 V3 as an example to explain how to directly connect a Solaris host to a two-controller storage system through iSCSI multi-path connections, as shown in Figure 3-5.
In this connection diagram, each of the two controllers is connected to a port on the host network adapter with a network cable. The IP address plan is detailed in Table 3-6.
Port Name |
Port Description |
IP Address |
Subnet Mask |
---|---|---|---|
Host.P0 |
Connects the Solaris host to Controller A on the storage system. |
192.168.5.5 |
255.255.255.0 |
Host.P1 |
Connects the Solaris host to Controller B on the storage system. |
192.168.6.5 |
255.255.255.0 |
Storage.A.P0 |
Connects Controller A on the storage system to the Solaris host. |
192.168.5.6 |
255.255.255.0 |
Storage.B.P0 |
Connects Controller B on the storage system to the Solaris host. |
192.168.6.6 |
255.255.255.0 |
IP addresses in this table are for reference only. Plan IP addresses based on site requirements.
Multi-Controller Storage
The following uses Huawei OceanStor 18800 V3 (four-controller) as an example to explain how to directly connect a Solaris host to a multi-controller storage system through iSCSI multi-path connections, as shown in Figure 3-6.
In this connection diagram, each of the four controllers is connected to a port on host network adapters with a network cable. The IP address plan is detailed in Table 3-7.
Port Name |
Port Description |
IP Address |
Subnet Mask |
---|---|---|---|
Host.P0 |
Connects the Solaris host to Controller A on the storage system. |
192.168.5.5 |
255.255.255.0 |
Host.P1 |
Connects the Solaris host to Controller B on the storage system. |
192.168.6.5 |
255.255.255.0 |
Host.P2 |
Connects the Solaris host to Controller C on the storage system. |
192.168.7.5 |
255.255.255.0 |
Host.P3 |
Connects the Solaris host to Controller D on the storage system. |
192.168.8.5 |
255.255.255.0 |
Storage.A.P0 |
Connects Controller A on the storage system to the Solaris host. |
192.168.5.6 |
255.255.255.0 |
Storage.B.P0 |
Connects Controller B on the storage system to the Solaris host. |
192.168.6.6 |
255.255.255.0 |
Storage.C.P0 |
Connects Controller C on the storage system to the Solaris host. |
192.168.7.6 |
255.255.255.0 |
Storage.D.P0 |
Connects Controller D on the storage system to the Solaris host. |
192.168.8.6 |
255.255.255.0 |
IP addresses in this table are for reference only. Plan IP addresses based on site requirements.