Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R002C50

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.51 hwStackLinkTopoAlarm

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.51 hwStackLinkTopoAlarm

Description

The system is a link-topo stack that contains more than two member switches.

A stack contains more than two member switches and is set up in chain topology.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Error

Mnemonic Code

hwStackLinkTopoAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.51

Alarm ID

0x0a762001

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.52 hwStackLinkTopoAlarmResume

Parameters

None

VB Parameters

None

Impact on the System

The stack has low reliability.

Possible Causes

A stack contains more than two member switches and is set up in chain topology.

Procedure

  1. Change the stack topology to ring topology.