Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R002C50

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
DEFEND_1.3.6.1.4.1.2011.5.25.165.2.2.7.2 hwCpcarDropPacketAlarmResume

DEFEND_1.3.6.1.4.1.2011.5.25.165.2.2.7.2 hwCpcarDropPacketAlarmResume

Description

Rate of packets to cpu lowered the CPCAR limit in slot [SlotId]. (Protocol=[Protocol])

The rate of protocol packets in the specified slot falls below the CPCAR values set for the protocol. The packet drop alarm is cleared.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwCpcarDropPacketAlarmResume

Trap OID

1.3.6.1.4.1.2011.5.25.165.2.2.7.2

Alarm ID

0x09632007

Alarm Type

qualityOfServiceAlarm

Raise or Clear

Clear

Match trap

DEFEND_1.3.6.1.4.1.2011.5.25.165.2.2.7.1 hwCpcarDropPacketAlarm

Parameters

Parameter Description

SlotId

Slot ID.

Protocol

Protocol type.

VB Parameters

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.165.2.1.7.1

hwCpcarDropPacketSlotStr

None

1.3.6.1.4.1.2011.5.25.165.2.1.7.2

hwCpcarDropPacketProtocol

None

1.3.6.1.4.1.2011.5.25.165.2.1.7.3

hwCpcarDropPacketPps

None

1.3.6.1.4.1.2011.5.25.165.2.1.7.4

hwCpcarDropPacketCbs

None

1.3.6.1.4.1.2011.5.25.165.2.1.7.5

hwCpcarDropPacketNum

None

Impact on the System

The rate of protocol packets in the specified slot falls below the CPCAR values set for the protocol. The packet drop alarm is cleared.

Possible Causes

The protocol packet rate in the specified slot falls below the CPCAR values set for the protocol within 30 minutes.

Procedure

  • This trap is informational only, and no action is required.