Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R002C50

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.2 hwStackLinkDown

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.2 hwStackLinkDown

Description

The interface Stack-Port is down. (StackPortName=Stack-Port[hwStackPortStackId]/[hwStackPortId])

The stack interface became Down.

Attribute

Attribute

Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

hwStackLinkDown

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.2

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the matching trap.

Parameters

Name Meaning

StackPortName

Indicates the name of a stack interface.

hwStackPortStackId

Indicates the stack ID of the device where the stack interface locates.

hwStackPortId

Indicates the ID of a stack interface.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.21.1.1

hwStackPortStackId

hwStackPortStackId;

hwStackPortId;

1.3.6.1.4.1.2011.5.25.183.1.21.1.2

hwStackPortId

hwStackPortStackId;

hwStackPortId;

1.3.6.1.4.1.2011.5.25.183.1.21.1.5 hwStackPortStatus

hwStackPortStackId;

hwStackPortId;

Impact on the System

A stack fails to be created or splits.

Possible Causes

  • The stack interface was shut down.
  • All physical interfaces became Down.
  • The stack link was faulty.

Procedure

  1. Check the connection and validity of stack cables. Run the display interface brief command to check the physical status and protocol status of the stack interface.

    • If the physical status of an interface is Down, check whether the cable connected to the interface is loosened or removed.
    • If the physical status of the interface is Up, go to step 2.

  2. Check whether the shutdown command was executed on the interface. Run the interface interface-type interface-number command to enter the stack interface view, and run the display this command to check whether the shutdown configuration exists.

    • If so, run the undo shutdown command.
    • If not, go to step 3.

  3. Collect traps, logs, and configurations, and contact technical support personnel.