Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R002C50

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
CLKM_1.3.6.1.4.1.2011.5.25.186.1.8.22 hwClockClusterTopoFail

CLKM_1.3.6.1.4.1.2011.5.25.186.1.8.22 hwClockClusterTopoFail

Description

Clock cluster inter-chassis synchronization topo compute failed.(hwClockClusterNewSyncType = [hwClockClusterNewSyncType], hwClockClusterNewTopoType = [hwClockClusterNewTopoType], hwClockClusterNewTopoLinkType = [hwClockClusterNewTopoLinkType], hwClockClusterNewTopoStatus = [hwClockClusterNewTopoStatus])

Clock synchronization tracing failed between chassis in a cluster.

Attributes

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwClockClusterTopoFail

Trap OID

1.3.6.1.4.1.2011.5.25.186.1.8.22

Alarm ID

0x09af203f

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

CLKM_1.3.6.1.4.1.2011.5.25.186.1.8.23 hwClockClusterTopoFailResume

Parameters

Parameter Description

hwClockClusterNewSyncType

Type of the inter-chassis synchronization clock.

hwClockClusterNewTopoType

Type of the inter-chassis synchronization topology.

hwClockClusterNewTopoLinkType

Type of the inter-chassis synchronization link.

hwClockClusterNewTopoStatus

Status of the inter-chassis synchronization topology.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.186.1.15.1.1

hwClockClusterSyncType

hwClockClusterSyncType

hwClockClusterTopoType

hwClockClusterTopoLinkType

1.3.6.1.4.1.2011.5.25.186.1.15.1.2

hwClockClusterTopoType

hwClockClusterSyncType

hwClockClusterTopoType

hwClockClusterTopoLinkType

1.3.6.1.4.1.2011.5.25.186.1.15.1.3

hwClockClusterTopoLinkType

hwClockClusterSyncType

hwClockClusterTopoType

hwClockClusterTopoLinkType

1.3.6.1.4.1.2011.5.25.186.1.15.1.4

hwClockClusterTopoStatus

hwClockClusterSyncType

hwClockClusterTopoType

hwClockClusterTopoLinkType

Impact on the System

Chassis in a cluster will fail to synchronize clock or time signals.

Possible Causes

The BITS interface's cable was removed.

Procedure

  1. Run the display current-configuration command to check whether configurations of clock-related interfaces are correct.

    • If so, go to step 2.
    • If not, go to step 3.

  2. Check whether inter-chassis cable connections are correct.

    • If so, go to step 5.
    • If not, go to step 4.

  3. Reconfigure attributes of clock-related interfaces.
  4. Troubleshoot cable connections.
  5. Collect alarm information, log information, and configuration of the device, and contact technical support.
  6. End.