Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R002C50

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ISIS_1.3.6.1.4.1.2011.5.25.24.2.4.12 hwIsisSystemIdAutoRecover

ISIS_1.3.6.1.4.1.2011.5.25.24.2.4.12 hwIsisSystemIdAutoRecover

Description

After a system ID conflict was detected within an IS-IS area, IS-IS changed the system ID automatically. (hwisisSysInstance=[integer], hwISISConflictSystemID=[opaque], hwISISAutoSysId=[opaque], hwISISLocalIP=[ipaddr], hwISISRemoteIP=[ipaddr])

After a system ID conflict was detected within an IS-IS area, IS-IS changed the conflicting system ID automatically.

Attributes

Attribute

Description

Alarm or Event

Event

Trap Severity

Informational

Mnemonic Code

hwIsisSystemIdAutoRecover

Trap OID

1.3.6.1.4.1.2011.5.25.24.2.4.12

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the matching trap.

Parameters

Parameter Description

hwisisSysInstance

IS-IS process ID

hwISISConflictSystemID

Conflicting system ID

hwISISAutoSysId

New system ID

hwISISLocalIP

IP address of the local device whose system ID conflicts with another system ID

hwISISRemoteIP

IP address of the remote device whose system ID conflicts with the local system ID

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.24.2.2.2

hwisisSysInstance

N/A

1.3.6.1.4.1.2011.5.25.24.2.2.7

hwIsisConflictSystemID

N/A

1.3.6.1.4.1.2011.5.25.24.2.2.8

hwIsisAutoSysId

N/A

1.3.6.1.4.1.2011.5.25.24.2.2.9

hwIsisLocalIP

N/A

1.3.6.1.4.1.2011.5.25.24.2.2.10

hwIsisRemoteIP

N/A

Impact on the System

After the conflicting system ID is changed automatically, LSPs will not be frequently updated, and routes will no longer flap.

Possible Causes

An IS-IS system ID conflict was detected in the topology, and IS-IS changed one of the conflicting system IDs automatically.

Procedure

  1. This trap message is informational only, and no action is required.
Translation
Download
Updated: 2019-03-20

Document ID: EDOC1000166558

Views: 203872

Downloads: 115

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next