Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R002C50

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.45 hwStackMemberPortSpeedDifferentAlarm

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.45 hwStackMemberPortSpeedDifferentAlarm

Description

The rates of member ports in a stack port are different. (hwStackPortName=[hwStackPortName])

The stack member ports have different rates.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwStackMemberPortSpeedDifferentAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.45

Alarm ID

0x09a22022

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.46 hwStackMemberPortSpeedDifferentAlarmResume

Parameters

Name Meaning

hwStackPortName

Indicates the name of the stack port.

VB Parameters

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.21.1.3

hwStackPortName

hwStackPortStackId

hwStackPortId

Impact on the System

Traffic may be interrupted on the stack port.

Possible Causes

Optical modules that mismatch the port rates are inserted into the stack member ports. For example, a 40GE optical module is inserted into a 100GE port.

Procedure

  1. Replace the optical modules that mismatch the port rates.