Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R002C50

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
MSTP_1.3.6.1.4.1.2011.5.25.42.4.2.1 hwMstpiPortStateForwarding

MSTP_1.3.6.1.4.1.2011.5.25.42.4.2.1 hwMstpiPortStateForwarding

Description

The port has been set to forwarding state. (InstanceID=[INTEGER], PortIndex=[INTEGER], IfIndex=[INTEGER], PortName=[STRING], PwName=[PwName])

The port entered the forwarding state.

Attribute

Attribute Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

hwMstpiPortStateForwarding

Trap OID

1.3.6.1.4.1.2011.5.25.42.4.2.1

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the matching trap.

Parameters

Parameter Description
InstanceID Indicates the instance ID.
PortID Indicates the port ID.
IfIndex Indicates the interface index.
PortName Indicates the port name.
PwName Indicates the pw name.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.42.4.1.19.1.1

hwMstpInstanceID

hwMstpInstanceID

1.3.6.1.4.1.2011.5.25.42.4.1.20.1.1

hwMstpInstanceID

hwMstpiPortIndex

1.3.6.1.2.1.31.1.1.1.1

hwMstpiPortIndex

ifName

Impact on the System

The network topology will change.

Possible Causes

The network topology changed.

Procedure

  • The network topology changed.
    1. View physical devices on the network to check whether a new physical link that has STP enabled is added.

      • If a new physical link that has STP enabled is added, go to Step 2.
      • If no new physical link that has STP enabled is added, go to Step 3.

    2. Check whether the added physical link is necessary.

      • If the added physical link is necessary, go to Step 3.
      • If the added physical link is unnecessary, go to Step 4.

    3. Run the display stp [ process process-id ] [ instance instance-id ] [ interface interface-type interface-number | slot slot-id ] [ brief ] command to check whether the interfaces are consistent with the STP calculation results.

      • If the interfaces are consistent with the STP calculation results, the alarm will be cleared.
      • If the interfaces are inconsistent with the STP calculation results, go to Step 5.

    4. Correctly deploy the network topology, and then check whether the alarm is cleared. If the alarm persists, go to Step 5.
    5. Collect trap, log, and configuration information, and contact technical support personnel.