No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R002C50

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
OSPF_1.3.6.1.2.1.14.16.2.5 ospfVirtIfConfigError

OSPF_1.3.6.1.2.1.14.16.2.5 ospfVirtIfConfigError

Description

A packet is received on the virtual interface from a router whose configuration conflicts with the local configuration. (VirtIfAreaId=[area-id], VirtIfNeighbor=[neighbor-router-id], ProcessId=[process-id], RouterId=[router-id], ConfigErrorType=[error-type], PacketType=[packet-type], InstanceName=[instance-name])

Configurations of the interfaces on the two ends of the virtual link were incorrect. The possible cause was that the configurations of the parameters conflicted.

Attribute

Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

ospfVirtIfConfigError

Trap OID

1.3.6.1.2.1.14.16.2.5

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the matching trap.

Parameters

Parameter Description

VirtIfAreaId

Indicates the area ID.

VirtIfNeighbor

Indicates the router ID of the neighbor on the virtual link.

ProcessId

Indicates the process ID.

RouterId

Indicates the ID of the local switch.

ConfigErrorType

Indicates the error type.
  • 1: Bad Version
  • 2: Area Mismatch
  • 3: Unknown Nbma Neighbour
  • 4: Unknown Virtual Neighbour
  • 7: NetMask Mismatch
  • 8: Hello Interval Mismatch
  • 9: Dead Interval Mismatch
  • 10: Option Mismatch
  • 11: Mtu Mismatch
  • 12: Duplicate RouterId

PacketType

Indicates the type of the packet.
  • 1: Hello packet
  • 2: DD packet
  • 3: Request packet
  • 4: Update packet
  • 5: Acknowledgement packet
  • 6: Update packet Retrans
  • 7: Update packet flood

InstanceName

Indicates the instance name.

VB

VB OID

VB Name

VB Index

1.3.6.1.2.1.14.1.1

ospfRouterId

N/A

1.3.6.1.2.1.14.9.1.1

ospfVirtIfAreaId

ospfVirtIfAreaId;

ospfVirtIfNeighbor;

1.3.6.1.2.1.14.9.1.2

ospfVirtIfNeighbor

ospfVirtIfAreaId;

ospfVirtIfNeighbor;

1.3.6.1.2.1.14.16.1.2

ospfConfigErrorType

N/A

1.3.6.1.2.1.14.16.1.3

ospfPacketType

N/A

Impact on the System

This trap message is generated after the virtual interface receives a packet indicating parameters are incorrectly configured.

Possible Causes

The configurations of the interfaces on the two ends of the virtual link conflicted.

Procedure

  1. Run the display ospf vlink and display current- configuration configuration commands to check whether the configurations of the two interfaces are consistent.

    • If so, go to Step 3.

    • If not, go to Step 2.

  2. Perform the following operations according to the networking:

    • If it is allowed to modify the configurations on the two interfaces to be consistent, run the following command to modify the configurations on the two interfaces to be consistent.

      • vlink-peer router-id [ dead dead-interval | hello hello-interval | retransmit retransmit-interval | smart-discover | trans-delay trans-delay-interval | [ simple [ plain plain-text | [ cipher ] cipher-text ] | { md5 | hmac-md5 | hmac-sha256 } [ key-id { plain plain-text | [ cipher ] cipher-text } ] | authentication-null | keychain keychain-name ] ] *
      Then, check whether the tap is cleared.
      • If so, go to Step 4.

      • If not, go to Step 3.

    • If it is not allowed to modify the configurations on the two interfaces to be consistent, go to Step 3.

  3. Collect the trap information, log information, and configuration of the switch, and contact technical support personnel technical personnel.
  4. End.
Translation
Download
Updated: 2019-03-20

Document ID: EDOC1000166558

Views: 194648

Downloads: 113

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next