Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R002C50

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
SYSTEM_1.3.6.1.4.1.2011.5.25.219.2.11.2 hwSystemConfigResume

SYSTEM_1.3.6.1.4.1.2011.5.25.219.2.11.2 hwSystemConfigResume

Description

The system configuration error has been rectified. ( EntityTrapFaultID = [EntityTrapFaultID])

The system configuration was corrected.

Attributes

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwSystemConfigError

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.11.2

Alarm ID

0x0d300004

Alarm Type

equipmentAlarm

Raise or Clear

Clear

Match trap

SYSTEM_1.3.6.1.4.1.2011.5.25.219.2.11.1 hwSystemConfigError

Parameters

Parameter Description

EntityTrapFaultID

Trap error codes.
  • EntityTrapFaultID=144128 indicates that the versions of the PAF and startup package were inconsistent.
  • EntityTrapFaultID=144130 indicates that the package versions of the master and slave boards were inconsistent.
  • EntityTrapFaultID=144133 indicates that the memory of the master and slave boards were inconsistent.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

N/A

Impact on the System

Services are not affected.

Possible Causes

A system configuration error was rectified.

Procedure

  • This alarm message is informational only, and no action is required.