Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R002C50

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
PIM_1.3.6.1.4.1.2011.5.25.149.4.0.3 invalid-join-prune

PIM_1.3.6.1.4.1.2011.5.25.149.4.0.3 invalid-join-prune

Description

PIM receives an Invalid Join/Prune message. (GroupMappingOrigin=[GroupMappingOrigin], GroupMappingAddrType=[GroupMappingAddrType], GrpAddr=[GrpAddr], GrpPfxLen=[GrpPfxLen], GroupMappingRPAddrType=[GroupMappingRPAddrType], RPAddr=[RPAddr], GroupMappingPimMode=[GroupMappingPimMode], InvJPAddrType=[InvJPAddrType], InvJPOriginAddr=[InvJPOriginAddr], InvJPGrpAddr=[InvJPGrpAddr], InvJPRpAddr=[InvJPRpAddr], NbrIfIndex=[NbrIfIndex], NbrAddrType=[NbrAddrType], NbrAddr=[NbrAddr], NbrUpTime=[NbrUpTime], NbrName=[NbrName], PimInstanceID=[PimInstanceID], PimInstanceName=[PimInstanceName])

PIM received invalid Join/Prune messages.

Attributes

Attribute

Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

invalid-join-prune

Trap OID

1.3.6.1.4.1.2011.5.25.149.4.0.3

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the matching trap.

Parameters

Parameter Description

GroupMappingOrigin

RP type

GroupMappingAddrType

Group address type

GrpAddr

Group address in the Join/Prune message

GrpPfxLen

Mask length of the multicast group address

GroupMappingRPAddrType

RP address type

RPAddr

RP address

GroupMappingPimMode

Current PIM mode

InvJPAddrType

Address type of the invalid Join/Prune messages

InvJPOriginAddr

Source address of the invalid Join/Prune messages

InvJPGrpAddr

Group address of the invalid Join/Prune messages

InvJPRpAddr

RP address of the invalid Join/Prune messages

NbrIfIndex

Index of the neighboring interface

NbrAddrType

Address type of the neighboring interface

NbrAddr

Address of the neighboring interface

NbrUpTime

Lifetime of the neighbor relationship

NbrName

Name of the neighboring interface

PimInstanceID

The ID of the instance to which the neighbor interface belongs.

PimInstanceName

The name of the instance to which the neighbor interface belongs.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.149.4.1.13.1.7

hwPimGroupMappingPimMode

hwPimGroupMappingOrigin;

hwPimGroupMappingAddressType;

hwPimGroupMappingGrpAddress;

hwPimGroupMappingGrpPrefixLength;

hwPimGroupMappingRpAddressType;

hwPimGroupMappingRpAddress;

1.3.6.1.4.1.2011.5.25.149.4.1.39

hwPimInvalidJoinPruneAddressType

N/A

1.3.6.1.4.1.2011.5.25.149.4.1.40

hwPimInvalidJoinPruneOrigin

N/A

1.3.6.1.4.1.2011.5.25.149.4.1.41

hwPimInvalidJoinPruneGroup

N/A

1.3.6.1.4.1.2011.5.25.149.4.1.42

hwPimInvalidJoinPruneRp

N/A

1.3.6.1.4.1.2011.5.25.149.4.1.2.1.6

hwPimNeighborUpTime

hwPimNeighborIfIndex;

hwPimNeighborAddressType;

hwPimNeighborAddress;

1.3.6.1.4.1.2011.5.25.149.4.1.2.1.16

hwPimNeighborIfName

hwPimNeighborIfIndex;

hwPimNeighborAddressType;

hwPimNeighborAddress;

1.3.6.1.4.1.2011.5.25.149.4.1.57

hwPimInstanceID

N/A

1.3.6.1.4.1.2011.5.25.149.4.1.60

hwPimInstanceName

N/A

Impact on the System

After the RP receives an invalid Join or Prune message, information about multicast members fails to reach the RP.

Possible Causes

Cause 1: The RP address carried in the received Join or Prune message was different from that specified on the device.

Cause 2: A Join or Prune message of (*.G) or (S, G, RPT) type was received but its group address was in the SSM range specified on the device.

Procedure

  • Cause 1: The RP address carried in the received Join or Prune message was different from that specified on the device.
    1. Run the display pim rp-info command to check whether the RP configurations of the device that sends the Join/Prune message are the same with that of the local device.

      • If the RP configurations of the device that sends the Join/Prune message are the same with that of the local device, go to Step 2.
      • If the RP configurations of the device that sends the Join/Prune message are different from that of the local device, configure a same RP for the devices.

    2. Collect the alarm information, log information, and configuration information, and then contact technical support personnel.
  • Cause 2: A Join or Prune message of (*.G) or (S, G, RPT) type was received but its group address was in the SSM range specified on the device.
    1. Run the display current-configuration command to check whether the SSM group address range on the device that sends the Join/Prune message is the same as that on the local device.

      • If the SSM group address range on the device that sends the Join/Prune message is the same as that on the local device, go to Step 2.
      • If the SSM group address range on the device that sends the Join/Prune message is different from that on the local device, configure a same SSM group address range for the devices.