No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R002C50

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
OSPF_1.3.6.1.4.1.2011.5.25.155.31.19 hwOspfv2GreaterAgeLsaRecived

OSPF_1.3.6.1.4.1.2011.5.25.155.31.19 hwOspfv2GreaterAgeLsaRecived

Description

OSPF receive LSA with greater Lsa-Age.(ProcessId=[ProcessId], AreaId=[AreaId], IfIndex=[IfIndex], NbrIPaddress=[NbrIpAddress], IfName=[IfName], NbrRtrId=[NbrRtrId], LsaId=[LsaId], LsaAge=[LsaAge])

This object indicates that the aging time of a received LSA is greater than 1800s.

Attributes

Attribute

Description

Alarm or Event

Event

Trap Severity

Informational

Mnemonic Code

hwOspfv2GreaterAgeLsaRecived

Trap OID

1.3.6.1.4.1.2011.5.25.155.31.19

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the matching trap.

Parameters

Parameter

Description

ProcessId

ID of an OSPF process

AreaId

Area ID

IfIndex

Interface index

NbrIPaddress

IP address of a neighbor

IfName

Interface name

NbrRtrId

Router ID of a neighbor

LsaId

LSA ID

LsaAge

Aging time of the LSA

VB Parameters

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.155.3.1.1

hwOspfv2ProcessIdIndex

hwOspfv2ProcessIdIndex

1.3.6.1.4.1.2011.5.25.155.6.1.9

hwOspfv2NbrRouterId

hwOspfv2ProcessIdIndex

hwOspfv2AreaIdIndex

hwOspfv2SelfIfnetIndex

hwOspfv2NbrIpAddrIndex

1.3.6.1.4.1.2011.5.25.155.6.1.5

hwOspfv2SelfIfName

hwOspfv2ProcessIdIndex

hwOspfv2AreaIdIndex

hwOspfv2SelfIfnetIndex

hwOspfv2NbrIpAddrIndex

1.3.6.1.4.1.2011.5.25.155.30.7

hwOspfv2LsaId

N/A

1.3.6.1.4.1.2011.5.25.155.30.8

hwOspfv2LsaAge

N/A

Impact on the System

LSA flapping or a route calculation error may occur.

Possible Causes

This object indicates that the aging time of a received LSA is greater than 1800s.

Procedure

  1. Run the display ospf lsdb command to check whether the value of the Age field is less than 1800s.

    • If the value of the Age field is greater than or equal to 1800s, check whether the value was changed manually.
      • If the value of the Age field was changed manually, no action is required, and go to Step 3.
      • If the value of the Age field was not changed manually, go to Step 2.
    • If the value of the Age field is less than 1800s, go to Step 2.

  2. Collect alarm information and configuration information, and then contact technical support personnel.
  3. End.
Translation
Download
Updated: 2019-03-20

Document ID: EDOC1000166558

Views: 196733

Downloads: 115

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next