Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R002C50

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
DEVM_1.3.6.1.4.1.2011.5.25.219.2.4.10 hwOpticalUnAuthorizedResume

DEVM_1.3.6.1.4.1.2011.5.25.219.2.4.10 hwOpticalUnAuthorizedResume

Description

The alarm on optical module not certified by Huawei Ethernet Switch was clearned.(EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=[EntityTrapFaultID], Reason=[Reason])

The alarm about optical modules that are not certified for Huawei Ethernet switches was cleared.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwOpticalUnAuthorizedResume

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.4.10

Alarm ID

0x08132154

Alarm Type

processingErrorAlarm

Raise or Clear

Clear

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.4.9 hwOpticalUnAuthorized

Parameters

Parameter Description

EntPhysicalIndex

Indicates the index of an entity.

EntPhysicalName

Indicates the name of an entity.

EntityTrapFaultID

Indicates the error code. The error code in this alarm is 145920.

Reason

Indicates the alarm cause.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

N/A

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

N/A

Impact on the System

None

Possible Causes

The alarm about optical modules that are not certified for Huawei Ethernet switches was cleared. Possible causes include:
  • The switch restarted.
  • Optical modules that are not certified for Huawei Ethernet switches were removed.
  • Optical modules that are certified for Huawei Ethernet switches were installed.
  • The alarm about optical modules that are not certified for Huawei Ethernet switches was disabled.

Procedure

  1. This alarm message is informational only, and no action is required.