Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R002C50

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.35 hwFabricLinkProtocolAlarm

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.35 hwFabricLinkProtocolAlarm

Description

The physical status of the fabric link for the logical port is up, but the protocol status is down. (hwStackFabricPort=[hwStackFabricPort])

The physical status of the fabric port link is Up, but the protocol status is Down.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwFabricLinkProtocolAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.35

Alarm ID

0x09a2201e

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.36 hwFabricLinkProtocolAlarmResume

Parameters

Name Meaning

hwStackFabricPort

Indicates the fabric port number.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.32.8

hwStackFabricPort

N/A

Impact on the System

The fabric port link fails.

Possible Causes

Cause 1: The fabric port link fails.

Cause 2: Packet reception on the port times out.

Procedure

  • Cause 1: The fabric port link fails.

    1. Run the display alarm active command to check whether a link alarm is generated. If a link alarm is generated, check the connection or configuration according to the reason for the alarm.
    2. Run the display stack link-state last-down-reason command to check the reason why the fabric port link becomes Down and check the connection or configuration according to the reason.
    3. Collect alarm, log, and configuration information, and contact technical support personnel.

  • Cause 2: Packet reception on the port times out.

    1. Collect alarm, log, and configuration information, and contact technical support personnel.

Translation