Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R002C50

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
FM_1.3.6.1.4.1.2011.6.30.18.1.0.5 hwAlarmClearedReportTrap

FM_1.3.6.1.4.1.2011.6.30.18.1.0.5 hwAlarmClearedReportTrap

Description

Notice NMS to clear active alarm.(AlarmClearedNum=[AlarmClearedNum],AlarmClearedSnList=[AlarmClearedSnList])

The NMS was notified to clear active alarms with specified sequence numbers.

Attributes

Attribute

Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

hwAlarmClearedReportTrap

Trap OID

1.3.6.1.4.1.2011.6.30.18.1.0.5

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the matching trap.

Parameters

Parameter

Description

AlarmClearedNum

Number of active alarms to be cleared

AlarmClearedSnList

List of the sequence numbers of active alarms to be cleared

VB Parameters

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.6.30.17.15

hwAlarmClearedNum

hwAlarmClearedNum

1.3.6.1.4.1.2011.6.30.17.16

hwAlarmClearedSnList

hwAlarmClearedSnList

Impact on the System

Services will not be affected.

Possible Causes

According to IETF standards, after an active alarm is manually cleared or is cleared because of the deletion of the associated object, the clearance event cannot be reported to the NMS. In this case, the device sends an hwAlarmClearedReportTrap notification to notify the NMS to clear the alarm.

Procedure

  • This trap message is informational only, and no action is required.