Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
EOAM-1AG_1.3.6.1.4.1.2011.5.25.136.1.6.32 hwDot1agCfmUnexpectedMEGLevel

EOAM-1AG_1.3.6.1.4.1.2011.5.25.136.1.6.32 hwDot1agCfmUnexpectedMEGLevel

Description

MEP received a CCM with unexpected MEG level. (MdIndex=[GAUGE],MaIndex=[GAUGE],MdName=[STRING],MaName=[STRING],MepId=[INTEGER])

The MD level carried in a CCM sent by the RMEP was different from that specified on the MEP.

Attributes

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwDot1agCfmUnexpectedMEGLevel

Trap OID

1.3.6.1.4.1.2011.5.25.136.1.6.32

Alarm ID

0x09ac0000

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

EOAM1AG_1.3.6.1.4.1.2011.5.25.136.1.6.33 hwDot1agCfmUnexpectedMEGLevelCleared

Parameters

Parameter Description
MdIndex Index of an MD table
MaIndex Index of an MA table
MdName Name of an MD
MaName Name of an MA
MepId ID of a MEP

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.136.1.1.3.2.1.3

hwDot1agCfmMdName

hwDot1agCfmMdIndex

1.3.6.1.4.1.2011.5.25.136.1.1.4.2.1.2

hwDot1agCfmMaName

hwDot1agCfmMdIndex

hwDot1agCfmMaIndex

1.3.6.1.4.1.2011.5.25.136.1.1.5.1.1.1

hwDot1agCfmMepIdentifier

hwDot1agCfmMdIndex

hwDot1agCfmMaIndex

hwDot1agCfmMepIdentifier

Impact on the System

CFM will fail.

Possible Causes

The MD level carried in a CCM sent by the RMEP was different from that specified on the MEP.

Procedure

  1. Run the display cfm mep [ md md-name [ ma ma-name [ mep-id mep-id ] ] ] command on both the MEP and RMEP to view the value of the Level field. Check whether the MD levels are the same.

    • If the MD levels are different, go to Step 2.

    • If the MD levels are the same, go to Step 3.

  2. Perform the following steps on the MEP:
    1. Run the undo cfm md name md-name command to delete existing MD configurations.
    2. Run the cfm md md-name level level command to reconfigure an MD the same as that on the RMEP.
    3. Run the display alarm active command to view the trap. Check whether the trap is cleared. If the trap persists, go to Step 3.