Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R002C50

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
BFD_1.3.6.1.4.1.2011.5.25.38.3.4 hwBfdSessReachLimitBindIf

BFD_1.3.6.1.4.1.2011.5.25.38.3.4 hwBfdSessReachLimitBindIf

Description

Try to build session, but the session number in the IO board with interface has reached the limit, the new session binding with interface can not be created. (ConfigurationName=[ConfigurationName], InterfaceName=[InterfaceName], SessionLimitPerBoard=[SessionLimitPerBoard])

The trap was generated when the number of BFD sessions bound to the interface on the interface board reached the PAF upper limit and no more BFD session bound to the interface can be set up.

Attributes

Attribute

Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

hwBfdSessReachLimitBindIf

Trap OID

1.3.6.1.4.1.2011.5.25.38.3.4

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the matching trap.

Parameters

Parameter

Description

ConfigurationName

Indicates the configuration name of the BFD session.

InterfaceName

Indicates the interface name.

SessionLimitPerBoard

Indicates the allowable maximum number of BFD sessions on each board.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.38.2.2.1.7

hwBfdSessConfBindIfName

hwBfdSessConfName

1.3.6.1.4.1.2011.5.25.38.1.4

hwBfdSessInterfaceLimitNumber

None

Impact on the System

Services will not be affected.

Possible Causes

New BFD sessions bound to the interface were still set up when the number of BFD sessions bound to the interface have reached the upper limit.

Procedure

  1. Run the display bfd statistics command to check whether the BFD_IO_SESSION_NUM on the board has reached the upper limmit.

    • If so, go to Step2.
    • If not, go to Step3.

  2. Delete the useless BFD session which bound to this interface, and then the BFD session about committed configuration will be set up. Go to step4.
  3. Collect configurations, trap messages, and log messages, and then contact technical support personnel.
  4. End.