Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R002C50

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.15 hwStackLinkLimitAlarm

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.15 hwStackLinkLimitAlarm

Description

The number of STACK links has reached the alarm threshold. (hwStackLocalIfName=[hwStackLocalIfName], hwStackCurrentLinkNum=[hwStackCurrentLinkNum], hwStackLinkAlarmThreshold=[hwStackLinkAlarmThreshold])

The number of available stack links is smaller than the alarm threshold.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwStackLinkLimitAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.15

Alarm ID

0x09a22014

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.16 hwStackLinkLimitAlarmResume

Parameters

Parameter Description

hwStackLocalIfName

Specifies the name of a stack port.

hwStackCurrentLinkNum

Specifies the number of available physical member ports in a stack port.

hwStackLinkAlarmThreshold

Specifies the alarm threshold for the number of stack links.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.32.1

hwStackLocalIfName

N/A

1.3.6.1.4.1.2011.5.25.183.1.32.14

hwStackCurrentLinkNum

N/A

1.3.6.1.4.1.2011.5.25.183.1.8

hwStackLinkAlarmThreshold

N/A

Impact on the System

Stack link bandwidth and reliability are reduced, and even stack split may occur.

Possible Causes

Some stack links become faulty, causing the number of available stack links to be smaller than the alarm threshold.

Procedure

  1. Run the display interface brief command to check information and status of physical member ports in a stack port.

    • If some physical member ports are Down, check whether their cables are loose.
    • If all physical member ports are Up, go to step 2.

  2. Increase the number of physical member ports in the stack port or run the stack port-link threshold command to set the alarm threshold of stack links to a smaller value.
  3. Collect trap messages, log messages, and configurations, and then contact technical support personnel.
Translation