Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R002C50

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
FCOE_1.3.6.1.4.1.2011.5.25.303.2.5 hwFCoETnNum

FCOE_1.3.6.1.4.1.2011.5.25.303.2.5 hwFCoETnNum

Description

The number of VN_Ports that belong to the same NPV instance exceeds the number of MAC addresses. (FCoE-port Index=[index], system MAC address quantity=[sysMacNum], VN_Port quantity =[vnPortNum])

The number of VN_Ports in the same NPV instance exceeds the number of system MAC addresses.

Attributes

Attribute

Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

hwFCoETnNum

Trap OID

1.3.6.1.4.1.2011.5.25.303.2.5

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the matching trap.

Parameters

Parameter Description

index

Index of the FCoE interface.

sysMacNum

Number of system MAC addresses.

vnPortNum

Number of VN_Ports.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.303.1.3

hwFCoEPortResource

N/A

Impact on the System

If the number of VN_Ports in the same NPV instance exceeds the number of system MAC addresses, MAC address conflicts may occur. If the conflicting ports belong to the same VLAN, services will be affected.

Possible Causes

When the number of VN_Ports of a NPV instance exceeds the number of system MAC addresses, VN_Ports are created continuously on the ENodes.

Procedure

  • Stop creating VN_Ports in the same NPV instance.
  • Run the undo fcoe role vn-port interface fcoe-port fcoe-port-id command to delete unnecessary VN_Ports.