Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R002C50

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
DEVM_1.3.6.1.4.1.2011.5.25.219.2.5.3 hwPowerFail

DEVM_1.3.6.1.4.1.2011.5.25.219.2.5.3 hwPowerFail

Description

A power module experienced a partial failure.(EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=[EntityTrapFaultID], Reason=[Reason])

The power module partially failed.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwPowerRemove

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.5.3

Alarm ID

0x0813001d

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.5.4 hwPowerFailResume

Parameters

Name Meaning

EntPhysicalIndex

Indicates the index of an entity.

EntPhysicalName

Indicates the name of an entity.

EntityTrapFaultID

Indicates the trap ID.
  • 136707

  • 136732

  • 136733

Reason

Indicates a possible cause.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

N/A

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

N/A

Impact on the System

A fault of the power module may cause insufficient power supply on the device. As a result, devices will be reset. Services are affected. This fault needs to be rectified.

Possible Causes

  • Cause 1 (EntityTrapFaultID=[136707]): The sub-module of the power module failed.

  • Cause 2 (EntityTrapFaultID=[136732]): Airflow direction of fans in power supplies is abnormal.

  • Cause 3 (EntityTrapFaultID=[136733]): The fan inside a power module fails.

Procedure

  • Cause 1: The sub-module of the power module failed.
    1. Collect traps, logs, and configurations, and contact technical support personnel.
  • Cause 2: Airflow direction of fans in power supplies is abnormal.
    1. Replace the power module. If the fault persists, collect traps, logs, and configurations, and contact technical support personnel.
  • Cause 3: The fan inside a power module fails.
    1. Power off the faulty power module and then replace it with another one.